Purpose. For measuring dew point by condensation method on moisture and hydrocarbons in natural gas.
Specifications.
- Ambient temperature operating range, °С –30…+30
- Measured dew point range °С –30…+20
- Measurement accuracy, °С 1
- Duration of one measurement, sec <180
- Number of measurements <50
- Weight, kg<20.
Application area. Gas transportation, energy.
Advantages. Higher accuracy, dew point measurement of natural gas with high moisture content or heavy hydrocarbons, measurement under arbitrary pressure with automatic recalculation of results up to a pressure of 3.96 MPa.
Description. The main body of the device is in explosion-proof design (flame-proof shell), controls are intrinsically safe. The measurement results are stored in the internal memory of the device and can be copied to a USB drive, as well as to a personal computer or an industrial automation system via the RS-485 interface.